Features
Ideal for high-acceleration and high-frequency operation of heavy loads
- Customization, including water cooling and forced air cooling
- Supports EtherCAT, MECHATROLINK-III, and CC-Link
Specifications and Dimensions
τLinear NVA-BL Type individual Specifications and Dimensions
| Motor model | NVA-BL | F002A2B | G00A2B | H00A2B | |
|---|---|---|---|---|---|
| Rated thrust | N | 540 | 720 | 900 | |
| Maximum thrust | N | 1,620 | 2,160(2,016*1) | 2,700(2,025*2) | |
| Rated output | W | 1,620 | 2,160 | 2,700 | |
| Rated current | A | 9.3 | 12.5 | 15.5 | |
| Maximum speed*2 | m/sec | 3.0 | 3.0 | 3.0 | |
| Applicable power supply | ACV | 200 | 200 | 200 | |
| Coil unit | Model | CLV-BL | F00A2B | G00A2B | H00A2B |
| Weight | kg | 2.9 | 3.9 | 5.2 | |
| Magnet base | Model | MBV-BL | Select from M00B (96 mm) / R00A (144 mm) | ||
| Weight | kg | M00B:3.3kg/R00A:4.9kg | |||
| Paired driver model | |||||
| VPH Series | NCR-H□ | 2152A-B-□□□ | 2332A-B-□□□, (2222A-B-□□□)*1 | 2332A-B-□□□, (2222A-B-□□□)*2 | |
| Download dimensions | |||||
| Motor model | NVA-BL | F002A2B | G00A2B | H00A2B | |
| Rated thrust | N | 540 | 720 | 900 | |
| Coil unit model | CLV-BL□**1 | PDF DXF STEP | PDF DXF STEP | PDF DXF STEP | |
| Magnet base model | MBV-BLM00B | PDF DXF STEP | |||
| MBV-BLR00A | |||||
* The specification values are those obtained when a heat sink (aluminum plate) is mounted on the coil unit and operated at an ambient temperature of 25°C. For details, refer to the individual specifications in the catalog.
*1 Shown in parentheses is the maximum thrust when a paired driver is used.
*2 Maximum speed for the motor. The actual speed depends on the sensor resolution. Refer to the Linear encoders section in the τLinear servo motor catalog.
**1 The □ of the coil unit model is the same as that of the motor model.
Common specifications
| Ambient temperature for use | 0 to 40℃ |
| Ambient humidity for use | 85%RH or less, no condensation allowed |
| Installation location | Avoid any harmful atmosphere including corrosive gas, grinding oil, metal dust, and oil. Indoors, away from direct sunlight. |
| Sea level | Sea level: 1,000 m or less |
| Installation direction | Horizontal, vertical |
| Cooling method | Natural cooling |
| Insulation class | Class F |
| Insulation withstand voltage | 1500 VAC, 1 minute |
| Vibration resistance | 1G (3 directions, 2 hours each) |
| Shock resistance | 10G (3 directions, 3 times each) |