Features
The high-efficiency magnet arrangement delivers greater cost-effectiveness as the stroke length increases
- Customization, including water cooling and forced air cooling
- Supports EtherCAT, MECHATROLINK-III, and CC-Link
Specifications and Dimensions
τLinear NLD-FL Type individual Specifications and Dimensions
| Motor model | NLD-FL | 30SA2A | 40SA2A | 60SA2A | 70SA2A | 85SA2A | |
|---|---|---|---|---|---|---|---|
| Rated thrust | N | 320 | 480 | 640 | 800 | 1,000 | |
| Maximum thrust | N | 960 | 1,440(1,200*1) | 1,920 | 2,400 | 3,000 | |
| Rated output | W | 960 | 1,440 | 1,920 | 2,400 | 3,000(2,380 *1) | |
| Rated current | A | 4.6 | 6.8 | 9.2 | 11.5 | 14.7 | |
| Maximum speed*2 | m/sec | 3.5 | 3.5 | 3.5 | 3.5 | 3.5 | |
| Applicable power supply | ACV | 200 | 200 | 200 | 200 | 200 | |
| Coil unit | Model | CLD-FL | 30SA2A | 40SA2A | 60SA2A | 70SA2A | 85SA2A |
| Weight | kg | 3.4 | 5 | 6.7 | 8.2 | 9.9 | |
| Magnet base | Model | MBD-FL | Select from 11SA (112 mm) / 33SA (336 mm) | ||||
| Weight | kg | 11SA:3.7kg/33SA:10.9kg | |||||
| Paired driver model | |||||||
| VPH Series | NCR-H□ | 2801A-B-□□□ | 2152A-B-□□□, (2801A-B-□□□)*1 | 2152A-B-□□□ | 2222A-B-□□□ | 2332A-B-□□□, (2222A-B-□□□)*1 | |
| Download dimensions | |||||||
| Motor model | NLD-FL | 30SA2A | 40SA2A | 60SA2A | 70SA2A | 85SA2A | |
| Rated thrust | N | 320 | 480 | 640 | 800 | 1,000 | |
| Coil unit model | CLD-FL□**1 | PDF DXF STEP | PDF DXF STEP | PDF DXF STEP | PDF DXF STEP | PDF DXF STEP | |
| Magnet base model | MBD-FL11SA | PDF DXF STEP | |||||
| MBD-FL33SA | PDF DXF STEP | ||||||
* The specification values are those obtained when a heat sink (aluminum plate) is mounted on the coil unit and operated at an ambient temperature of 25°C. For details, refer to the individual specifications in the catalog.
*1 Shown in parentheses is the maximum thrust when a paired driver is used.
*2 Maximum speed for the motor. The actual speed depends on the sensor resolution. Refer to the Linear encoders section in the τLinear servo motor catalog.
**1 The □ of the coil unit model is the same as that of the motor model.
Common specifications
| Ambient temperature for use | 0 to 40℃ |
| Ambient humidity for use | 85%RH or less, no condensation allowed |
| Installation location | Avoid any harmful atmosphere including corrosive gas, grinding oil, metal dust, and oil. Indoors, away from direct sunlight. |
| Sea level | Sea level: 1,000 m or less |
| Installation direction | Horizontal, vertical |
| Cooling method | Natural cooling |
| Insulation class | Class F |
| Insulation withstand voltage | 1500 VAC, 1 minute |
| Vibration resistance | 1G (3 directions, 2 hours each) |
| Shock resistance | 10G (3 directions, 3 times each) |