The high-efficiency magnet arrangement delivers greater cost-effectiveness as the stroke length increases
- Customization, including water cooling and forced air cooling
- Supports EtherCAT, MECHATROLINK-III, and CC-Link
Specifications and Dimensions
τLinear NLD-AM Type individual Specifications and Dimensions
| Motor model | NLD-AM | 10SA2A | 20SA2A | 30SA2A | 40SA2A | |
|---|---|---|---|---|---|---|
| Rated thrust | N | 50 | 95 | 150 | 200 | |
| Maximum thrust | N | 150 | 275 | 450 | 500 | |
| Rated output | W | 150 | 285 | 450 | 600 | |
| Rated current | A | 1.8 | 3.4 | 5.2 | 6.8 | |
| Maximum speed*1 | m/sec | 3.5 | 3.5 | 3.5 | 3.5 | |
| Applicable power supply*2 | ACV | 200 | 200 | 200 | 200 | |
| Coil unit | Model | CLD-AM | 10SA2A | 20SA2A | 30SA2A | 40SA2A |
| Weight | kg | 0.4 | 0.7 | 1.1 | 1.4 | |
| Magnet base | Model | MBD-AM | Select from 12SA (120 mm)/24SA (240 mm) | |||
| Weight | kg | 12SA:1.4kg/24SA:2.7kg | ||||
| Paired driver model | ||||||
| VPH Series | NCR-H□ | 2201A-B-□□□ | 2401A-B-□□□ | 2801A-B-□□□ | 2801A-B-□□□ | |
| Download dimensions | ||||||
| Motor model | NLD-AM | 10SA2A | 20SA2A | 30SA2A | 40SA2A | |
| Rated thrust | N | 50 | 95 | 150 | 200 | |
| Coil unit model | CLD-AM□**1 | PDF DXF STEP | PDF DXF STEP | PDF DXF STEP | PDF DXF STEP | |
| Magnet base model | MBD-AM12SA | PDF DXF STEP | ||||
| MBD-AM24SA | PDF DXF STEP | |||||
* The specification values are those obtained when a heat sink (aluminum plate) is mounted on the coil unit and operated at an ambient temperature of 25°C. For details, refer to the individual specifications in the catalog.
*1 Maximum speed for the motor. The actual speed depends on the sensor resolution. Refer to the Linear encoders section in the τLinear servo motor catalog.
*2 It may be possible to combine with a 100 VAC specification servo driver. However, the rating will be reduced, so clarify the specifications and contact our sales representative.
**1 The □ of the coil unit model is the same as that of the motor model.
Common specifications
| Ambient temperature for use | 0 to 40℃ |
| Ambient humidity for use | 85%RH or less, no condensation allowed |
| Installation location | Avoid any harmful atmosphere including corrosive gas, grinding oil, metal dust, and oil. Indoors, away from direct sunlight. |
| Sea level | Sea level: 1,000 m or less |
| Installation direction | Horizontal, vertical |
| Cooling method | Natural cooling |
| Insulation class | Class F |
| Insulation withstand voltage | 1500 VAC, 1 minute |
| Vibration resistance | 1G (3 directions, 2 hours each) |